Key questions about this property
The answers below summarize the purpose, scope, default effect, and review scenarios for this property.
| What does it do? |
A comma-separated list enables matching simulation logger prefixes and disables others; when the list is blank or unset, all prefixes are allowed. |
| What area does it affect? |
Event Management simulations |
| What does the default mean? |
No out of the box record exists and the scripts that read it pass no fallback value. |
| When should you review it? |
When limiting simulation logging to specific logger prefixes or restoring logging for all prefixes |
Property record
No out of the box record exists. ServiceNow scripts read this property; create it to change the behavior.
| Property name |
sn_em_tbac.sim_logger_names |
| Type |
Not stated |
| Application |
Not stated |
| Default value |
Not set |
| Description |
Not stated |
Sources
Official references and nearby text excerpts where this property appears.
Used in
Out of the box artefacts that read this property. Append the path to your instance URL to open the record and see how the value is used.
Script include: EMTagSimLogger
It controls which simulation logger prefixes are enabled: a comma-separated list allows matching prefixes and disables others; when unset or blank, all prefixes are allowed. No default value is supplied.
/sys_script_include.do?sys_id=0e0264ff33490a50aca7e7d32d5c7bef